Àü·Â°èÅë½Ç½Ã°£¸ðÀÇÀåÄ¡(RTDS) | ||
---|---|---|
±Ô°Ý | RTDS Simulator 2Racks/Portable RTDS(GPC,WIF,IRC) | |
Á¦Á¶»ç | RTDS LTD(CANADA) | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
½ÅÈ£ºÐ¼®±â(Signal Analyzer) | ||
±Ô°Ý | Display:6¨ö Digit.Expansion Channels:10,DC Volts-Sensitivity:100nV-Maximum Reading:1000V-Basic Accuracy:0.002%.AC Volts(TRMS):Bandwidth:3Hz~300kHz.Ohms(2/4Wire),DC Amps,AC Amps(TRMS)µî | |
Á¦Á¶»ç | KEITHLEY | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
ÀÓÀÇÆÄÇü¹ß»ý±â | ||
±Ô°Ý | ä³Î:Dual(2ä³Î),»çÀÎÆÄ ÁÖÆļö ¹üÀ§:1uHz-100MHz,±¸ÇüÆÄ ÁÖÆļö ¹üÀ§:1uHz to 50 MHz,ÆÞ½ºÀÓÀÇÆÄÇü ¹üÀ§:1uHz to 50 MHz,Frequency Resolution:1uHz or 12 Digits,Amplitude Resolution:0.1mVp-p or 4Digits | |
Á¦Á¶»ç | Tektronix | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
´Ùä³ÎÀüÀ§Â÷ÃøÁ¤±â | ||
±Ô°Ý | MV2000(8ch-25ms/10ch,20ch,30ch,40ch,48ch-125ms), Àü¿ø: AC power supply, 100-264 VAC,Display:Trend, Graph, Digital, Overview Áö¿ø, ÃÖ´ë 10/36 GroupÁö¿ø | |
Á¦Á¶»ç | Yokogawa | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
°¨¸¶¼±ºÐ±¤½Ã½ºÅÛ | ||
±Ô°Ý | °í ¼øµµ °Ô¸£¸¶´½ °ËÃâ±â-¹°Áú : P-ŸÀÔ µ¿ÃàÇü °í ¼øµµ °Ô¸£¸¶´½,ÃøÁ¤ ¿¡³ÊÁö ¹üÀ§ : 40keV¡10MeV,Àü±âÀû, ±â°èÀû ³Ã°¢±â,µðÁöÅÐ °¨¸¶¼± ºÐ±¤±â ¹× MCA ¿¡¹Ä·¹ÀÌ¼Ç ¼ÒÇÁÆ®¿þ¾î,³³ Â÷Æóü | |
Á¦Á¶»ç | AMETEK | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
ÀÓÇÇ´ø½ºÃøÁ¤±â | ||
---|---|---|
±Ô°Ý | Frequency range 6440B:20 Hz to 3 MHz > 1800 steps,Accuracy of set frequency ¡¾0.005%,Pre-set frequencies:20, 25, 30, 40, 50, 60, 80, 100, 120, 150 repeats for each decade | |
Á¦Á¶»ç | Wayne Kerr Electronics | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
°íÁÖÆĽºÆåÆ®·³ºÐ¼®±â(Spectrum Analyzer) | ||
±Ô°Ý | Frequency Range:9kHz to 7.1,13,20GHz,Tuning Resolution:1Hz, Measurement Range:DANL to +30dBm, Display: Full SVGA LCD 8.4 inch | |
Á¦Á¶»ç | Anritsu | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
Á¢ÁöÀúÇ× ¹× ´ëÁö °íÀ¯ÀúÇ× Çؼ®ÇÁ·Î±×·¥ | ||
±Ô°Ý | CDEGS Software Packge(SES Software), Auto grid pro¿Ü 9°³ Packge, RESAP-Soil Resistivity Analysis, MALT-Grounding Analysis, MALZ-Frequency Domain Grounding Analysis, AutoGround Design | |
Á¦Á¶»ç | SES | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
ÀüÀÚÀåÇؼ®ÇÁ·Î±×·¥ÆÐÅ°Áö | ||
±Ô°Ý | FLUX2D/3DVer.10.2.4;CAD interface:DXFÇü½Ä import,Geometry(Å©±â,À§Ä¡),Mesh,Material,ȸ·Î¼ÒÀÚ,°æ°èÁ¶°ÇµîÀÇ ÆĶó¹ÌÅÍÈ,´ÙÁßÁÂÇ¥°èÁö¿ø(Àü¿ª,Áö¿ª,Á÷±³,¿øÅë,±¸¸é ÁÂÇ¥°è),Automatic Build Face/Volume | |
Á¦Á¶»ç | MAGSOFT | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
NI PXI ½Ã½ºÅÛ(Lab-View) | ||
±Ô°Ý | CPU : Intel Core 2 Duo processor T7400 (2.16 GHz dual core) for PXI, System bandwidth : Up to 132 MB/s Up to 1 GB/s, Bus : PXI, SCXI Isolated Module, SCXI Filter Module µî(PXI8106,1050) | |
Á¦Á¶»ç | National Instruments | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
¹æ»ç´Éºñ»ó¹æÀçÅ°Æ® | ||
---|---|---|
±Ô°Ý | Gamma dose rate survey meter (FH40GL),Alpha/Beta Contamination detector (FHZ742),NaI(Tl) 2" x 2" Scintillation detector with holding device (FHT502P),High range Teletector (FH40TG) | |
Á¦Á¶»ç | Thermo Electron(Erlangen) GmbH | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
ÀúÁØÀ§ ¾ËÆÄ/º£Å¸ °è¼ö±â(PIC-WPC-9550) | ||
±Ô°Ý | Active diameter 2 inch gas flow proportional detector for 80¥ìg/cm3, Alpha:<0.05 CPM for typical Alpha, Beta:<0.4 CPM for typical Beta, Alpha<1.5% slope/100V, Beta<2.5% slope/100V,Cross talk:< 0.1 % | |
Á¦Á¶»ç | Protean Instrument Corporation | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
Àü·Â¼±·Î Á÷·Äº¸»ó ½Ç½ÀÀåÄ¡ | ||
±Ô°Ý | Line 1 Simulated Length : 200 km, Line 1 Simulated Nominal Power : 4500MW, Line 2 Simulated Length : 300 km, Line 2 Simulated Nominal Power : 3000 MW, Compensation : 17%, 25%, 34% | |
Á¦Á¶»ç | Labvolt | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
½ÅÈ£ºÐ¼®±â KIT | ||
±Ô°Ý | ´ë¿ªÆø:1GHz,½Ç½Ã°£»ùÇøµ¼Óµµ:5/10/20/40GS/s,·¹ÄÚµå±æÀÌ:50/100/200M,ä³Î:4ch | |
Á¦Á¶»ç | Tektronix(USA) | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
AC/DC Àü·ùÇÁ·Îºê | ||
±Ô°Ý | TCPA300-TCP312(30amps,100MHz)/TCP303(150amps,15MHz) | |
Á¦Á¶»ç | Tektronix(USA) | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
ÈÞ´ë¿ëÁÖÆļöºÐ¼®±â(°í¼º´É¸ÖƼ¹ÌÅÍ) | ||
---|---|---|
±Ô°Ý | Fluke 289 Digital Multimeter Kit;50,000 Ä«¿îÆ®¿¡ 320x240 (1/4 VGA) µµÆ® ¸ÅÆ®¸¯½º µð½ºÇ÷¹ÀÌ,TrendCapture¸¦ ÀÌ¿ëÇÑ ÀúÀåµÈ µ¥ÀÌÅ͵éÀÇ ÀçÈ®ÀÎ ±â´É,0.025 % basic dc accuracy,100 kHz AC bandwidth | |
Á¦Á¶»ç | FLUKE(USA) | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
ÆÄÇüºÐ¼®±â | ||
±Ô°Ý | DPO4054 ¿À½Ç·Î½ºÄÚÇÁ;1GHz, 500MHz, 350MHz ´ë¿ªÆø ¸ðµ¨,2CH ¹× 4CH,»ùÇà ¼Óµµ´Â ÃÖ´ë 5GS/s,10M »ùÇ÷¹ÄÚµå±æÀÌ,ÀÔ·ÂÀü¾Ð100V~240V(¡¾10%), ÀÔ·ÂÀü¿ø ÁÖÆļö47Hz~66HZ(100V~240V),400Hz(100V~132V) | |
Á¦Á¶»ç | Tektronix(USA) | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
ÆÄÇüÀúÀå½ÇÇèÀåÄ¡ | ||
±Ô°Ý | DL750 ScopeCorder(DL750 main unit) | |
Á¦Á¶»ç | ¿ä²¿°¡¿Í ÀνºÆ®·ç¸ÕÆ®ÄÚ¸®¾Æ(ÁÖ) | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
Àü·ÂÇ°ÁúºÐ¼®ÀåÄ¡ | ||
±Ô°Ý | PM6000;Up to 6 Wattmeter channels, 0.02%reading and 0.05%range accuracy, 10MHz bandwidth(40MSPS sampling) | |
Á¦Á¶»ç | Voltech | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
¿È»óÄ«¸Þ¶ó(TVS-500EX) | ||
±Ô°Ý | Number of Detector/Picture Elements:320(H)*240(V),Observation Display Range:-40~500¡ÆC,Wavelength Range:8-14¥ìm | |
Á¦Á¶»ç | NEC Avio | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
Àü·ÂºÐ¼®±â(ºÐ»êÀü¿øºÐ¼®½Ã½ºÅÛ) | ||
---|---|---|
±Ô°Ý | 18~28¡ÆC, RH¡Â70%, Test Voltage:AC0.05~5kV/DC:0.05~6kV Constant Voltage, Detection Current:AC-1mA~20mA,DC-1mA~10mA, Rasistance Range:0.1M§Ù~50G§Ù | |
Á¦Á¶»ç | Chroma(ŸÀÌ¿Ï) | |
´ë¿©¿©ºÎ | º¸À¯Áß | |
°úµµÇö»óÃøÁ¤½Ã½ºÅÛ | ||
±Ô°Ý | PowerXplorer PX5, Tests at 50/60 and 400Hz, Meets MIL Standard 1399 Testing, Eight channel,4voltage&4current, intuitive color touch screen, AC/DC applications | |
Á¦Á¶»ç | Dranetz-BMI | |
´ë¿©¿©ºÎ | º¸À¯Áß | |